Editorial

Usefulness of the new Spectral-Domain Optical Coherence Tomography (SD-OCT) devices in the study of degenerative dementias夽 Utilidad de los nuevos dispositivos de tomografía de coherencia óptica de dominio espectral para el estudio de las demencias degenerativas Elena García Martín ∗ , Isabel Fuertes Lázaro, Francisco Javier Fernández Tirado, Luis Emilio Pablo Júlvez Servicio de Oftalmología, Hospital Universitario Miguel Servet, Zaragoza, Spain

Neurodegenerative diseases group a family of cognitive disorders such as multiple sclerosis or Alzheimer, Parkinson or Creutzfeldt-Jacobs. Said cognitive disorders are due to an increase in cellular death processes and are associated to changes in behavior and alteration of many bodily activities including balance, movement, speech, breathing and cardiac function.Alzheimer’s disease is the most frequent cause of dementia in old age. It is estimated that in our country 500,000 people have this disease and, due to the progressive aging of our population, this number could quadruple in the next 50 years with devastating consequences not only for the sufferers and their families but also to the very stability of our health system. Alzheimer’s disease is characterized by the presence in the brain of patients of 2 aberrant structures, senile plates and neurofibrillary tangles, loss of synapses (mainly between hippocampus and cortical neurons) and axon deterioration. In Parkinson’s disease there is a selective loss of dopaminergic neurons, mainly through brain basal ganglions. Mammal retina contains dopaminergic neurons which are in charge of regulating the receptive field of ganglionic cells to provide

contrast sensitivity and chromatic vision.1 Previous studies have demonstrated that the extension of dopamine in retinal cells is lower in patients with degenerative diseases.2 The pathogenesis of multiple sclerosis is not entirely defined, although the majority of authors agree that it is caused by the concurrence of inflammation, demyelinization and axon damage processes. Said axonal damage appears in the early stages of the disease and can be monitored by studying the retina nervous fiber layer (RNFL). This layer is formed by the axons of ganglionic cells and therefore does not contain myelin.3 There is no specific evidence to diagnose degenerative dementiae. Symptoms can vary from one individual to another and could be similar to those of other diseases, particularly in the early stages. The diagnostic criteria are different in each hospital even though some are standardized such as the Poser and McDonald criteria for multiple sclerosis in which clinical findings must be associated to the presence of specific signs in neuroimaging tests.4,5 At this point in time, none of the standardized criteria for degenerative diseases include neuro-ophthalmological explorations even though a



Please cite this article as: García Martín E, et al. Utilidad de los nuevos dispositivos de tomografía de coherencia óptica de dominio espectral para el estudio de las demencias degenerativas Arch Soc Esp Oftalmol. 2011;86:347–50. ∗ Corresponding author. E-mail address: [email protected] (E. García Martín). 2173-5794/$ – see front matter © 2011 Sociedad Española de Oftalmología. Published by Elsevier España, S.L. All rights reserved.

348

a r c h s o c e s p o f t a l m o l . 2 0 1 1;8 6(1 1):347–350

substantial number of authors suggest that, on the basis of the usefulness demonstrated by RNFL analysis for the diagnostic and follow-up of these diseases, optic coherence tomography (OCT) should be included in the diagnostic criteria. Previous studies with time domain OCT (Stratus, Carl Zeiss Meditec, Dublin) have registered acceptable specificity and sensitivity values for diagnosing said neurodegenerative diseases.6,7 However, to date no sensitivity and specificity data have been published for the new spectral domain OCT instruments. A preliminary study carried out with Cirrus HD OCT (Carl Zeiss Meditec, Dublin) and Spectralis OCT (Heidelberg, Engineering Inc, Heidelberg, Germany) observed that both devices sample high sensitivity (90% with Cirrus and 93% with Spectralis) with an acceptable specificity (85 and 87%, respectively) for diagnosing multiple sclerosis. The higher performance of spectral domain OCT devices compared with the previous time domain OCT devices is beyond doubt because the quality, resolution and reproducibility of its images and measurements have increased. However, some ophthalmologists have wondered about the improvements provided by spectral domain OCT for studying said neurodegenerative diseases. In this regard, it is to be pointed out that the advantages in this field of ophthalmology are quite remarkable: - In the first place, new spectral domain OCT devices apply highly developed technology that allows simultaneous measurement of echoes and noise reduction, producing images with less artifacts, greater reproducibility and enhanced definition of the retinal structures and layers. The Cirrus HD OCT device is capable of taking measurements with a resolution of 5/1000 mm and over 67 million different information points with the use of infrared technology. On the other hand, Spectralis OCT simultaneously analyzes multiple wavelengths of the reflected light spectrum at a speed over 100 times faster than the previous time domain OCT and capturing about 40,000 sections per second. One of the main differences between Spectralis OCT and Cirrus OCT is the combination with confocal scanning (Confocal Scanning Laser Ophthalmoscope) that provides simultaneous images with enhanced image contrast and detail as well as exclusively analyzing the focal point information. Another significant difference is that the Eye Tracking technology of the Spectralis device is able to recognize ocular movements and guide the scanner as it allows control of the image during acquisition. - The majority of spectral domain OCT allow threedimensions reconstructions of retina and optic nerve images. - Some OCT, such as Spectralis, allow the operator to regulate the scanner in order to adapt it to the size of the eye. This translates into the acquisition of high quality images and reliable measurements in highly myopic eyes in which time domain OCT could hardly focus on the retina. - The software of most spectral domain OCT devices includes a follow-up function in which the device marks anatomical references of each eye. This allows operators to carry out subsequent scans at exactly the same location to detect whether during the follow-up of patient pathology modifications have occurred in the measurements and structures

of each retina area or sector. As previous time domain OCT devices did not have said function, it was commonplace to observe retinal thickness changes which did not match true changes but could be caused by slight movements of the eye or head of the patient, by repeating the scan in a different anatomic location or by changes in the scanning circle location. - The new spectral domain OCT devices enable the acquisition of volume cross sections. By analyzing each one of the data contained in volume information it is possible to study any section in that area and not only the recorded tomographic section. This technology exhibits clear advantages vis-à-vis radial sections made with time domain OCT devices because the volumetric scan controls all the areas in detail and prevents the exclusion of any area in the monitoring and follow-up of pathologies. - Some spectral domain OCT devices include protocols with specific application in Neuro-ophthalmology (Fig. 1). At present, there is only one application of this type included in clinic: the Nsite axonal analytics application of Spectralis OCT that provides among others the RNFL-N pattern in which the acquisition of images during scanning starts and ends in the nasal quadrant of the optic nerve head, so that in the temporal sector the reproducibility and reliability of these measurements are increased. The importance in this scanning change lies in that the temporal quadrant is precisely that which exhibits early alterations in neurodegenerative diseases.8 Other protocols included in the Nsite Axonal Analytics application of Spectralis OCT are the PMB pattern which focuses on the papillomacular bundle and the nervous fibers surrounding the macula, performing an isotropic scanning that has the drawback of requiring high acquisition times and good patient cooperation but yields a vast amount of information about the thickness of the main bundle that transmits the stimuli collected in the macula photoreceptors (Fig. 1); the OHN-N Pattern, utilized to display papillary edema with 3-D reconstructions and is particularly useful for studying optic neuritis; the volume-in-vertical pattern in which scans are captured at right angles to the nervous fibers, allowing a cross section view, and finally the Enhanced Depth Imaging pattern that carries out a special analysis of the optic disc displaying the lamina cribrosa and therefore the area where axons are covered by myelin. At this point in time there is no efficient treatment for degenerative dementia, even though dozens of labs all over the world are actively pursuing the identification of new genes and risks involved in these pathologies which could contribute to clarify the physiopathological background and to identify new therapeutic targets. One of the main current problems in neurodegenerative diseases, particularly Alzheimer’s and Parkinson’s, is that when the diagnostic is reached the brain has already suffered extensive and irreparable damage. For this reason, it is urgent to find biomarkers to detect the disease at significantly earlier stages, even prior to symptoms, when any therapeutic strategy would have greater possibilities of success. And in this regard, neuro-ophthalmological exploration can play an important role as a useful tool for

a r c h s o c e s p o f t a l m o l . 2 0 1 1;8 6(1 1):347–350

RNFL thickness with Cirrus OCT RNFL Protocol

Papillomacular array thickness with Spectralis OCT PMB Protocol

RNFL thickness with Spectralis OCT RNFL glaucoma protocol

RNFL thickness with Spectralis OCT RNFLNaxonal protocol

349

Fig. 1 – Retina nervous fiber layer (RNFL) thickness assessment in a patient with recent Parkinson’s disease diagnostic without ophthalmological symptoms, utilizing various spectral domain optic coherence tomography (OCT) devices: Cirrus (RNFL thickness protocol), Spectralis with papillomacular bundle protocols (PMB), RNFL thickness with glaucoma application (RNFL) and RNFL thickness with axonal application (RNFL-N). We identified differences between the measurements of different devices and analysis protocols, revealing a subclinical reduction in the RNFL thickness, particularly in the left eye.

diagnosing and following up said neurodegenerative pathologies. Some studies have evidenced a good correlation between numerological dysfunction in patients with ME, measured with the EDSS scale (Expanded Disability Status Scale) and RNFL defect measured with OCT.9–12 However, the association between RNFL thickness measurements and the characteristics of neurological diseases has not yet been studied with spectral domain devices. In a preliminary study carried out on 30 eyes of Parkinson’s patients, we have observed a significant correlation between the Mini-mental cognitive dysfunctions test score (Mental State Examination) and the mean and temporal RNFL thicknesses measured with the RNFL-N Pattern of the Nsite axonal application of Spectralis OCT. However, we have not observed an association between the Mini-mental test score and RNFL thickness measurements made with the classic glaucoma protocol of Spectralis (RNFL) or with those taken by Cirrus OCT. We have also observed that the RNFL-N and PMB patterns of the Spectralis Nsite Axonal application are more sensitive than the RNFL protocols of Spectralis and Cirrus to detect defects in RNFL secondary to neurodegenerative diseases.

Some authors suggest that OCT could substitute nuclear magnetic resonance as the “princeps” test for assessing patients with neurodegenerative diseases. However, many neuro-ophthalmologists regard this assertion as excessively ambitious because OCT only assesses a very small part of the central nervous system (SNC), specifically that corresponding to the retina ganglion cells, and even though neurodegenerative diseases tends to affect the SNC in a diffuse manner, considerable variability has been observed between the areas exhibiting greater axonal deterioration depending on said different pathologies as well as great individual variability. Accordingly, we found patients with multiple sclerosis in incipient stages with significant RNFL thickness reduction (e.g. if they have exhibited inflammatory outbreaks at the optic nerve level). Even so, we have observed subjects with the same disease in more advanced stages or progressive forms that hardly exhibit any RNFL thickness reduction. In conclusion, the new protocols designed by OCT manufacturers that include specific applications for neuroophthalmology could provide significant advantages in the assessment of said patients, allowing neurologists to base some of the diagnostic and therapeutic techniques on neuroophthalmological exploration, leading to a consultation of

350

a r c h s o c e s p o f t a l m o l . 2 0 1 1;8 6(1 1):347–350

important synergies between neurology and ophthalmology services in hospitals.

references

1. Bodis-Wollner. Retinopathy in parkinson disease. J Neural Transm. 2009;116:1493–501. 2. Price MJ, Feldman RG, Adelberg D, Kayne H. Abnormalities in color vision and contrast sensitivity in Parkinson’s disease. Neurology. 1992;42:887–90. 3. Palace. Inflammation versus neurodegeneration: consequences for treatment. J Neurol Sci. 2007;259:46–9. 4. Poser CM, Paty DW, Scheinberg L, McDonald WI, Davis FA, Ebers GC, et al. New diagnostic criteria for multiple sclerosis: guidelines for research protocols. Ann Neurol. 1983;13:227–31. 5. McDonald WI, Compston A, Edan G, Goodkin D, Hartung HP, Lublin FD, et al. Recommended diagnostic criteria for multiple sclerosis: guidelines from the International Panel on the diagnosis of multiple sclerosis. Ann Neurol. 2001;50:121–7. 6. Naismith RT, Tutlam NT, Xu J, Shepherd JB, Klawiter EC, Song SK, et al. Optical coherence tomography is less sensitive than visual evoked potentials in optic neuritis. Neurology. 2009;73:46–52.

7. Serbecic N, Aboul-Enein F, Beutelspacher SC, Graf M, Kircher K, Geitzenauer W, et al. Heterogeneous pattern of retinal nerve fiber layer in multiple sclerosis. High resolution optical coherence tomography: potential and limitations. PLoS One. 2010;5:e13877. 8. Garcia-Martin E, Pueyo V, Almarcegui C, Martin J, Ara JR, Sancho E, et al. Risk factors for progressive axonal degeneration of the retinal nerve fibre layer in multiple sclerosis patients. Br J Ophthalmol. 2011. 9. Garcia-Martin E, Pueyo V, Martin J, Almarcegui C, Ara JR, Dolz I. Progressive changes in the retinal nerve fiber layer in patients with multiple sclerosis. Eur J Ophthalmol. 2010;20:167–73. 10. Petzold A, De Boer JF, Schippling S, Vermersch P, Kardon R, Green A, et al. Optical coherence tomography in multiple sclerosis: a systematic review and meta-analysis. Lancet Neurol. 2010;9:921–32. 11. García-Martín E, Pueyo V, Fernández J, Almárcegui C, Dolz I, Martín J, et al. Atrophy of the retinal nerve fibre layer in multiple sclerosis patients, Prospective study with two years follow-up. Arch Soc Esp Oftalmol. 2010;85:179–85. 12. García-Martín E, Pueyo V, Fernández J, Martín J, Ara JR, Almarcegui C, et al. Effect of treatment in loss of retinal nerve fibre layer in multiple sclerosis patients. Arch Soc Esp Oftalmol. 2010;85:209–14.